4807
Safety Center 4807
Safety valves & groups✓Official SYR Oceanic product
⤓Documentation & manuals available
☎Technical advice & support
Description
For connecting unvented (pressurised) water heaters up to a maximum of 560 litres in accordance with DIN 1988 and DIN 4807. Certified by DVGW and acoustic approval class 1. The Safety Center 4807 comprises a connection for an additional cold-water consumer, a check valve with test facility, a double isolation system, a membrane pressure relief valve, an anti-legionella valve with integrated shut-off valve for maintenance, a membrane expansion tank of 12 or 18 litres, a mounting plate with screw connection for adjusting the distance to the wall, and a system check. Body made of bronze. Heads/cartridges for the membrane pressure relief valve in 6, 8 and 10 bar are included.
Technical specifications
| Min. operating pressure | 2 bar |
|---|---|
| Max. operating pressure | 16 bar |
| Max. operating temp. | 30 °C cold water inlet temperature |
| Medium | drinking water |
| Response pressure | 6, 8, 10 bar |
| Flow rate DN 20 | 2,0 m3/h at Dp 0,2 bar |
| Flow rate DN 20 | 4,0 m3/h at Dp 1,0 bar |
| ABP-Nr. | PA - IX 7728/L |
| Component identification | TUV-SV-10-545-DN-W-N-p |
Order numbers
| Variant / size | Order number |
|---|---|
| 4807, 12 l - MAG | 4807.20.006 |
| 4807, 18 l - MAG | 4807.20.007 |